首页 > 供应产品 > Fixed ultrasonic flowmeter TDS-100F DN50mm-700mm M2 Transducer Liquid Flow Meter
Fixed ultrasonic flowmeter TDS-100F DN50mm-700mm M2 Transducer Liquid Flow Meter
浏览: 783
品牌: AERMANDA
Model: TDS-100F
Origin: Made In China
Label: Wall-mount flowmeter , TDS-100F , flow meter
单价: 170.00元/Piece
最小起订量: 1 Piece
供货总量:
发货期限: 自买家付款之日起 天内发货
有效期至: 长期有效
最后更新: 2024-05-24 22:31
 
详细信息

Description:

Is stationary time difference ultrasonic flowmeter flow body could be water, sea water, or oil, uniform liquid slurry, conduct electricity or not, corrosive or no corrosive liquid can be measured. 

Widely used in industrial field of various liquid flow metering online, which host is divided into standard wall hanging type, plate type, hanging type explosion-proof, the use of different field in order to meet user needs.

 

Product features

Low fixed ultrasonic flowmeter with large planning integrated circuits CPLD, table process, accuracy is higher.

Price, high reliability, high performance, good applicability, full display in Chinese.

Day, month and year flow accumulation function, can record run 64 days before the operation, the first 64 months, the first five years of accumulated flow operation.

On low, the power management function, can record, electricity and traffic on 64 times before, can be manually or automatically compensate to reduce flow losses.

Low effectively overcome the wall of the ultrasonic signal attenuation and rough surface of the pipe to scattering of ultrasonic signal from surface reduce the energy consumption of ultrasonic signal.

Low overcame a signal to a small amount of sediment, suspended particles and bubbles, the effect of improved flow measurement accuracy, especially suitable for pipe flow measurement.

When using a dedicated open hole tool that sensor in the zone without water supply installation, unique belt roller disassembly, installation method, does not affect the normal production, 

at any time to complete the on-line replacement and maintenance.

 

Linearity

Better than ±1%.

Accuracy 

±1% of reading at rates >0.6 ft/s (0.2m/s). Assume a fully developed flow profile.

Repeatability

±0.2%.

Velocity

±0.03 ~ ±105 ft/s 
(±0.01 ~ ±30 m/s), bi-directional

Measurement Period

0.5s

Display

LCD with backlight.  2x20 letters.

Keypad

4x4-key membrane keypad with 
tactile feedback

Units

English (U.S.) or metric.

Outputs

Analogue output: 4-20mA or 0-20mA current output. Impedance 0~1kW. Accuracy 0.1%. .

Isolated OCT output: for frequency output (0~9,999Hz), alarm driver, or totaliser pulse output, ON/OFF control, etc.
Relay output 1A@125VAC or 2A@30VDC. For ON/OFF control, alarm driver, totaliser output, etc.

Internal Alarm (Buzzer): user programmable.
External Alarm Driver: alarm signal can be transmitted to Relay or OCT output terminals to drive an external alarm. 

RS-232 serial port. 

Input

Five channel 4-20mA current inputs for signals such as temperature, pressure, liquid level, and etc.. Accuracy 0.1%.
Two of the five input channels are wired to terminal blocks. The remaining three channels are optional.

Enclosure

Die-cast aluminum enclosure.

Protection Class:  IP65 (NEMA 4X).

Size: 9.88x7.56x3.15 (251x192x80mm3) for standard version

Clamp-on

S2-type: for pipe size  (DN15~DN100mm)

M2-type: for pipe size (DN50~DN700mm)

L2-type: for pipe size (DN300~DN6,000mm)

Liquid Types 

Virtually all commonly used clean liquids.

Liquids with small quantity of tiny particles may also be applicable. Particle size should be less than 75um, particle concentration less than 10,000ppm. 

Liquids should contain no or very minor air bubbles.

Examples are chilled/hot water, sea water, waste water, chemical liquids, oil, crude oil, alcohol, beer, etc.

Liquid Temp

(0C - 160C) for clamp-on transducer. Higher temperatures can be accommodated. Consult us for assistance.

(0C - 160C) for wetted transducer.

Pipe Size 

1 ~ 240 (DN15mm ~ DN6,000mm).

Pipe Material

All metals, most plastics, fiber glass, etc.  Allow pipe liner.

Cable

Shielded transducer cable. Standard length 15 (5m). Can be extended to 1640 (500m).  Contact us for longer cable requirement.

Power

AC: 240V DC: 8VDC~36VDC

Power consumption: < 2W

Weight

Standard main unit: 6.6lb (3kg) 

 

Transducer

Standard S2 type

Standard M2 type

Standard L2 type

 

 

Suitable pipe diameter

DN15-DN100mm

DN50-DN700mm

DN300-DN6000mm

 

 

Fluid temperature

0°c-160°c

0°c-160°c

0°c-160°c

 

 

Outer size

45×30×30mm

60×45×45

80×70×55

 

 

Quality

75g

250g

528g

 

 

 

Standard Packing:

TDS-100F Ultrasonic Flowmeter 

Clamp Fixture                                

Standard M2 Transducer

2 x 5m Signal Cable

 

If you need other transducer or extend the signal cable length, please contact us.