High performance! alternator generator for sale 6.5KW-1000KW
Main feature:
BTL brand Stamford series three-phase AC synchronous brushless alternator reaches revelant standards of IEC and GB755. It is combined with the diesel engine into the diesel generating set movable power plant, extensively used in the locations where need the power frequency power supply as land, universal enterprise, residential area and so on.
1) Coupled with any permanent magnetic generators, providing invariable excitation on all occasions.
2) Comply with the most common standard in term of GB755, IEC60034, BS5000, VDE0530, and CSAC22.2-100.
3)12-end reconnects able winding terminals to get different voltages.
4) Standard "H" insulation class.
5) Convenient installation and maintenance for leas-end rotated diodes and adapter connected bolts.
6) Standard sealed maintenance-free bearings.
7) Standard IP23 protection, optional severe environment protection.
Parametres Of Stamford Series Alternators | ||||||||
Model | 50Hz | 60Hz | Dimension: LxWxH (CM) | Weight with package (KG) | ||||
kw | kva | kw | kva | Single bearing | Double bearing | Single bearing | Double bearing | |
BTL164A | 6.5 | 8.1 | 8.2 | 10.2 | 52x53x58 | 60x53x58 | 95 | 101 |
BTL164B | 8.8 | 11 | 11 | 13.8 | 52x53x58 | 60x53x58 | 102 | 108 |
BTL164C | 10.8 | 13.5 | 13.5 | 16.9 | 52x53x58 | 60x53x58 | 110 | 116 |
BTL164D | 12.8 | 16 | 16 | 20 | 52x53x58 | 60x53x58 | 116 | 122 |
BTL184E | 18 | 22.5 | 23 | 28.8 | 58x53x58 | 65x53x58 | 133 | 141 |
BTL184F | 22 | 27.5 | 27.5 | 34.4 | 68x53x58 | 73x53x58 | 156 | 164 |
BTL184G | 25 | 31.3 | 30 | 37.5 | 68x53x58 | 73x53x58 | 172 | 180 |
BTL184H | 30 | 37.5 | 37.5 | 46.9 | 72x53x58 | 78x53x58 | 226 | 230 |
BTL184J | 34 | 42.5 | 40 | 50 | 72x53x58 | 78x53x58 | 236 | 240 |
BTL224C | 34 | 42.5 | 42 | 52.5 | 80x53x77 | 81x53x77 | 255 | 275 |
BTL224D | 40 | 50 | 50 | 62.5 | 80x53x77 | 81x53x77 | 270 | 295 |
BTL224E | 48 | 60 | 56 | 70 | 88x53x77 | 90x53x77 | 290 | 315 |
BTL224F | 58 | 72.5 | 70 | 87.5 | 88x53x77 | 90x53x77 | 330 | 345 |
BTL224G | 68 | 85 | 78 | 97.5 | 94x53x77 | 94x53x77 | 370 | 385 |
BTL274C | 80 | 100 | 94 | 117.5 | 89x63x86 | 93x63x86 | 415 | 435 |
BTL274D | 96 | 120 | 110 | 137.5 | 89x63x86 | 93x63x86 | 435 | 460 |
BTL274E | 112 | 140 | 134 | 167.5 | 99x63x86 | 104x63x86 | 485 | 510 |
BTL274F | 128 | 160 | 152 | 190 | 99x63x86 | 104x63x86 | 530 | 550 |
BTL274G | 145.6 | 182 | 174.8 | 218.5 | 106x63x86 | 109x63x86 | 580 | 600 |
BTL274H | 160 | 200 | 196 | 245 | 108x63x86 | 113x63x86 | 630 | 650 |
BTL274J | 184 | 230 | 224.8 | 281 | 114x68x89 | / | 760 | 790 |
BTL274K | 200 | 250 | 239.2 | 299 | 114x68x89 | / | 760 | 790 |
BTL314C | 200 | 250 | 240 | 300 | 126x73x95 | 135x73x95 | 910 | 950 |
BTL314D | 240 | 300 | 288 | 360 | 126x73x95 | 135x73x95 | 975 | 1015 |
BTL314ES | 260 | 325 | 315 | 394 | 126x73x95 | 135x73x95 | 1055 | 1095 |
BTL314E | 280 | 350 | 336 | 420 | 126x73x95 | 135x73x95 | 1055 | 1095 |
BTL314FS | 304 | 380 | 365 | 456 | 135x73x95 | 144x73x95 | 1183 | 1223 |
BTL314F | 320 | 400 | 384 | 480 | 135x73x95 | 144x73x95 | 1183 | 1223 |
BTL354C | 400 | 500 | 440 | 550 | 146x84x100 | 154x84x100 | 1350 | 1350 |
BTL354D | 440 | 550 | 475.2 | 594 | 146x84x100 | 154x84x100 | 1450 | 1450 |
BTL354E | 488 | 610 | 570.4 | 713 | 146x84x100 | 154x84x100 | 1598 | 1598 |
BTL354FS | 500 | 625 | 580 | 725 | 154x84x100 | 162x84x100 | 1753 | 1753 |
BTL354F | 536 | 670 | 620 | 775 | 154x84x100 | 162x84x100 | 1753 | 1753 |
BTL404B | 600 | 750 | 684 | 855 | 168x95x130 | 186x95x130 | 2020 | 2030 |
BTL404C | 640 | 800 | 733 | 966 | 168x95x130 | 186x95x130 | 2040 | 2050 |
BTL404D | 728 | 910 | 834 | 1043 | 168x95x130 | 186x95x130 | 2100 | 2110 |
BTL404E | 800 | 1000 | 916 | 1145 | 168x95x130 | 186x95x130 | 2260 | 2280 |
BTL404F | 900 | 1130 | 1019 | 1274 | 168x95x130 | 186x95x130 | 2490 | 2500 |
BTL404G | 1000 | 1250 | 1109 | 1386 | 178x95x130 | 206x95x130 | 2820 | 2830 |
Specification of Alternator:
Enclosure
IP21-23(NEMA 1) is standard for all industrial and marine generators .
Shaft & Keys
All alternator rotors are dynamically balance to better than Bs6861 P.1,G2.5 for minimum vibration in operation .Two bearing generators are balanced with a half-key. electric dynamo is used in diesel generator.
Terminal and terminal box
The 3Phase alternators had 12 ends brought out to the terminal box .The terminals are put on the non drive end. The box is equipped with removable panels.
Voltage regulation
Voltage regulation refers to the change of voltage from no-load to full-load with power factor ranging from 0.8 to 1 and 3%s fluctuation of the speed of engines .Voltage is adjusted using a trimmer on the AVR.
Telephone interference
THF(as defined by BS4999 Part 40) is better than 2%. TIF(as defined by ASAC50.12) is better than 50.
Radio interference
The absence of brush-gear and the high quality AVR ensure low levels of interference with radio transmissions. RFI suppression may be supplied if required .
Damper Winding
The alternators incorporate a damper winding in order to ensure good parallel running with mains network and other machines. Inserted into the shoes of the poles are the bars of the damper winding which are connected together at each end of the poles to form a closed cage. This arrangement provides the alternator with excellent damping against the torsinal vibration that occurs during changes in load and when running in parallel.
Warranty: | ||||
1. Since gen-set reached the agreed destination, its main parts will be guaranteed within 12 months or 1000 hours. | ||||
(subject to the earlier mature term). | ||||
2. We take charge of all troubles caused by gen-set’s fault and repair according to the regulation stipulated by | ||||
original plants. | ||||
3. Factors not accordance with the regulation of original plants such as fragile parts, daily consumed components, | ||||
wrong operating, lack of maintenance are not include in the quality guarantee. |