perating Principle
The impact body,which is equipped with tungsten carbide,impact velocities are measured at the 1mm point from the work piece in the following way:
the integrated permanent magnet will produce directly proportional voltage with the impact velocity.
The Leeb hardness values are calculated by the following formula:
HL=1000X(Vb/Va)
Feature |
Pen type design, self contained (Impact device and display integrated): no cables. |
The unique large-screen OLED color display (1.77-inch OLED Screen) integrated hardness tester in the world |
|
Interchangeable D impact device /DL impact device can achieve one unit dual use; can be used in the restricted area measurement. |
With battery compartment, battery can be replaced. Using standard AAA Lithum battery. |
Highly accuracy in any impact direction (360 degree), automatically identify impact direction and gravity compensation |
Easy Operation, the four soft keys above the screen achieve the various functions.
|
Instrument Specifications |
|
Display Type |
1.77 inch OLED with resolution 160x128 pixels |
Hardness Scale |
HL, HB, HRB, HRC, HV, HS. σb. |
Measuring Range |
HLD (200-960) HRC(19.8-68.5) HB(30-651) HV(80-976) HS(26.4-99.5) HRB(13.5-100).σb.(375-2639) |
Impact Device |
D type impact device (Standard); DL type impact device |
Accuracy |
±6HLD (HLD=800), Repeatability < 6HLD (HLD=800) |
Measuring direction |
360 degree by manual setting |
Material |
Steel & Cast Steel, Stainless Steel, GC IRON, NC IRON, Cast Aluminum alloy, Macht metal, Copper-tin alloy, Brass, Forged Steel |
Resolution |
1HL, 1HV, 1HB, 0.1HRB, 0.1HRC, 0.1HS |
Calibration |
Automatic |
Language |
English, Chinese |
Memory: |
1000 groups ,each group include 6 testing result and 1 average value |
Communication |
USB port, used for recharging and data transmission |
Software |
LmVIEW Software for transmission, storage, and printing |
Power |
AAA Polymer lithium battery ,Capacity of 600 MA/H,voltage:3.7 V, warning under low voltage |
Instrument Shut-off |
AUTO OFF after 3 minutes of inactivity |
Temperature |
-10 to +50 Degrees Celsius |
Net Weight |
110g with D type impact device,125g with DL type impact device |
Size |
150mm*46mm*23mm |
Standard |
GB/T 17394-1998, ASTM A956 |
Standard delivery:
Main unit (With D type impact device)
Impact device DL
HLD value Standard Calibration Block
DataView software
USB Communication cable
Small supporting ring
Cleaning brush
Recharger
User`s manual
Suitcase
Optional accessories:
Standard calibration test block
Standard supporting ring
Special supporting rings
Small supporting ring